Configure I/O Panels
Alloy Access sites can control multiple doors with just one controller using Input & Output panels.
The second section down on the Controllers page is the SIO Panels section.

Select the Add button on the right side (This will open up more options to add the MR52)
Fill out the fields accordingly:
Type in the name. Note: It is recommended to name the controller associated (Telecom: MR1, Leasing MR1, Maintenance MR1)
Select the model of your expansion panel
Assign the address (refer to the installation manual for Address DIP switch positions and baud rate)
Select the port (this will be TB3 on the MR52, referring to the physical terminal designation on the board itself)
Repeat this process for each additional board that is needed, remembering to address the board(s) sequentially